- New Ultrasonic, cross-correlation transit time method for flow measurement and PT100 Class B 4 wire for temperature measurement.
- New Heat/Energy calculation is designed to comply with EN1434 section 6.
- Flow Range – 0.1m/sec to 20m/sec bi-directional
- Display – 64 x 240 pixels graphic display
- Set-up via 16 key control panel
- ‘A’ Transducers in mounting rail:– 13mm OD to 115mm OD pipes
- ‘B’ Transducers in mounting rail:– 50mm OD to 2000mm OD pipes.
- Battery or mains operation
- Rechargeable NiMH battery
- Battery Life – 14 hours (2.5 hours charge time), depending on load
- Power – 110 – 240VAC +/-10% supply via PSU
- 4 user selectable languages including English, German, French and Spanish
- Accuracy Pipe ID > 75mm – ±0.5% to ±2% of flow reading for flow rate >0.2m/s
- Accuracy Pipe ID 13-75mm – ±3% of flow reading for flow rate >0.2m/s
- CE approved